‘V’

The MATADOR™ V-Baffle is the ideal system for creating a unique atmosphere within a room space that combines simplicity and symmetricity. The baffle is a ‘V’ shaped strip which can be easily clamped onto the carrier. They are perfect for places with high ceiling levels and open spaces. Baffles are further ideal for suppressing noise effluence and can contribute to the improvement of the acoustics of a space where sound quality is important.

Specifications

Raw Material

Aluminium Alloy 3000 series complying with (ASTM B 209M) or
Hot-dipped galvanized steel; complying with ASTM A653; Zinc coating as per requested.

Standard is Z120/G40

Sizes

Length: up to 4000
Width: angle degree of your choosing, but no less than 20 degree angle
Height: up to 300
Gap size: As per your request.

+ Custom sizes available on request

+ Custom sizes available on request

Thickness

Aluminium: 0.5 – 1.0 and
Galvanized Steel: 0.5 – 0.7

Surface Finish

Plain or Perforated

Insulation

Acoustic Black Fleece; Royalin®; Heat bonded nonwoven and non-flammable sound-absorbent acoustic black felt with surface-burning characteristics for flame-spread index = 5 and smoke-developed index = 25 as per ASTM E84.

Coating

Polyester Coating: (5µ (Back) + 20µ (Face)).
Polyester Powder Coating: (70µ -80µ)

High Performance Coatings like PESDF, PVDF and POLYAMIDE are available upon request.

Edge

Square Edge

Suspension

Matador® Baffle Carrier

Performance

Acoustics

Tested and compliant for noise reduction, sound absorption and sound attenuation.
Acoustic Black Fleece only: Maximum NRC = 0.80 as per ASTM C423.
DNCW = 46 as per BS EN 20140-9.
Acoustic Black Fleece with Rockwool as per ASTM C612 has a maximum NRC = 0.98.
Maximum CAC achieved: 46 db.

Anti-Bacterial

Stove enameled finish with anti-bacterial properties that prohibits bacterial growth as per JIS Z2801:2000

Fire Performance

Non-Combustible as per BS 476: Part 6.
Class 1 Surface Spread of Flame as per BS 476 Part 7.
Black Fleece is Non-Flammable Class A as per ASTM E84.

Light Reflectance

The light reflectance of the ceiling is 0.85 and tested as per ASTM E 1477

Humidity & Corrosion

Humidity Resistance = 95% as per ASTM D2477
Corrosion Resistance as per ASTM B 117-73, salt spray tested for 1000 hours.

Leed

Environmentally friendly material with processes contributing to LEED-NC building requirements

Finishes

RAL Colour
Wooden Finish
Special Finish

Technical Drawing