Search
Close this search box.

-

‘I’

The MATADOR™ I-baffle is the more simple type of baffle and is basically a flat sheet with half ‘W’ edges; one side for hooking onto the carrier and the other to mask the slimness. Or we can have it directly flat all the way which can be integrated into your gypsum ceiling. The product creates a unique and sleek presence when in close proximity.

Specifications

Raw Material

Aluminium Alloy 3000 series complying with (ASTM B 209M) or
Hot-dipped galvanized steel; complying with ASTM A653; Zinc coating as per requested.

Standard is Z90/G30

Sizes

Length: up to 4000
Height: up to 500
Gap size: As per your request.

+ Custom sizes available on request

+ Custom sizes available on request

Thickness

Aluminium: 0.5 – 1.0 and
Galvanized Steel: 0.5 – 0.7

Surface Finish

Plain or Perforated

Insulation

Acoustic Black Fleece; Royalin®; Heat bonded nonwoven and non-flammable sound-absorbent acoustic black felt with surface-burning characteristics for flame-spread index = 5 and smoke-developed index = 25 as per ASTM E84.

Coating

Polyester Coating: (20µ (Back) + 20µ (Face)).
Polyester Powder Coating: (70µ -80µ) (both sides)

High Performance Coatings like PESDF, PVDF and POLYAMIDE are available upon request.

Edge

Square Edge

Suspension

Matador® Baffle Carrier

Performance

Acoustics

Tested and compliant for noise reduction, sound absorption and sound attenuation.
Acoustic Black Fleece only: Maximum NRC = 0.80 as per ASTM C423.
DNCW = 46 as per BS EN 20140-9.
Acoustic Black Fleece with Rockwool as per ASTM C612 has a maximum NRC = 0.98.
Maximum CAC achieved: 46 db.

Anti-Bacterial

Stove enameled finish with anti-bacterial properties that prohibits bacterial growth as per JIS Z2801:2000

Fire Performance

Non-Combustible as per BS 476: Part 6.
Class 1 Surface Spread of Flame as per BS 476 Part 7.
Black Fleece is Non-Flammable Class A as per ASTM E84.

Light Reflectance

The light reflectance of the ceiling is 0.85 and tested as per ASTM E 1477

Humidity & Corrosion

Humidity Resistance = 95% as per ASTM D2477
Corrosion Resistance as per ASTM B 117-73, salt spray tested for 1000 hours.

Leed

Environmentally friendly material with processes contributing to LEED-NC building requirements

Finishes

RAL Colour
Wooden Finish
Special Finish

Technical Drawing